AS 2047 · AS/NZS 4420 series

AS 2047
Window & Door Testing

NATA-accredited performance testing for windows and external glazed doors to support compliance with Australian requirements.

What the test tells you

Independent evidence.
Built for real performance.

Windows and glazed doors are expected to do far more than simply open, close and keep the glass in place. They need to withstand the wind pressures, weather exposure and everyday operation expected at their intended location while helping protect the building from water ingress, excessive air leakage and structural failure.

SIIGMATIC provides NATA-accredited performance testing for windows and external glazed doors to support compliance with AS 2047. Testing is carried out using the relevant AS 4420 methods and can assess deflection under wind load, operating force, air infiltration, water penetration resistance and ultimate strength.

The result is independent evidence of how a window or door system actually performs. Testing establishes the performance ratings that manufacturers and fabricators rely upon when determining where their products can be used, including the appropriate serviceability and ultimate wind pressures and water penetration resistance.

For Australian window manufacturers, and particularly AGWA members, proper AS 2047 test evidence should sit behind the performance claims made for every system. AGWA itself recommends that purchasers verify that windows have been tested to AS 2047 at a NATA-accredited facility and retain the appropriate compliance documentation and test evidence.

Following successful testing, SIIGMATIC provides a NATA-endorsed test report documenting the tested configuration and its achieved performance, giving manufacturers, specifiers and customers credible evidence that the product has been independently tested against the relevant Australian requirements.

Typical scope

What we can
put under test.

01

Deflection

Measure frame and sash movement under the nominated serviceability pressure.

02

Operating force

Check that the product still operates within required limits after loading.

03

Air infiltration

Measure uncontrolled air leakage through the closed product.

04

Water penetration

Expose the specimen to pressure and water to assess resistance to leakage.

05

Ultimate strength

Apply the nominated ultimate pressure to assess structural resistance.

Your testing day

Prepared, private
and professionally run.

We run a controlled one-company-at-a-time booking format and prepare clients before they arrive, so the day is about testing the product rather than discovering the process as you go.

Private

One company at a time

Private booked laboratory access helps protect confidential product development and keeps the programme focused.

Prepared

Pre-test briefing

Know the practical requirements, test sequence and specimen preparation before you arrive.

Comfortable

Dedicated client suite

Kitchenette, fridge, bathroom, viewing window and camera feeds while testing proceeds.

Supported

Experienced local team

Technical personnel who can explain both the test and the Australian context around it.

Attendance and safety

The laboratory is a work zone. Attendance, PPE and who may enter the test area are confirmed during the pre-test preparation so there are no surprises on the day.

Lab questions

Before you book.

Do I need to test every size?

AS 2047 uses product classification and test-specimen rules agreed during pre-test review rather than requiring every manufactured size to be physically tested. The correct test matrix depends on the product family and claimed ratings.

Can we use the lab for development before certification?

Yes. Development testing can be scoped separately so design changes can be made before a final accredited test campaign. That keeps development work separate from certification.

Not sure about specimen, method or scope?

Talk before you ship it.

Ask the laboratory →